Acoustic Enclosure for filter installation
For reducing the noise of a filter installation and fan, Alara-Lukagro has received an order from Naaykens for the delivery of an acoustic enclosure. The enclosure is at Agco in Asbach-Bäumenheim.
Customer
Naaykens
End customer
Agco
The filter installation gives a compressed air blast every 30 seconds with a measured value of approximately 86/91 dB (A) at a distance of 1 meter. The desired value is less than 62/70 dB (A) at 1 meter distance. In addition, the enclosure must be provided with an opening so that sufficient fresh air can enter for cooling the ventilation motor and the enclosure must be accessible through a door.
Based on the desired dimensions, Alara-Lukagro has made an acoustic enclosure of 5.40 (l) x 4.85 (w) x 4.68 (h) meters. For access to the installation, the enclosure is equipped with a soundproof double leaf door of 1.80 (w) x 2.10 (h) meters. The ventilation openings of the enclosure are equipped with AL-R/300V acoustic louvres of 0.5 x 0.5 meters.
More information?
Are you facing a similar challenge?
Contact us with your questions and we will be delighted to advise you on a suitable solution for your project.